  hih-5030/5031 series low voltage humidity sensors description the hih-5030/5031 series low voltage humidity sensors operate down to 2.7 v, often ideal in battery-powered systems where the supply is a nominal 3 v. the hih 5030/5031 complements our existing line of 5 v smd (surface mount device) humidity sensors. smd packaging on tape and reel allows for use in high volume, automated pick and place manufacturing, eliminating lead misalignment to printed circuit board through-holes. the hih-5030/5031 series humidity sensors are designed specifically for high volume oem (original equipment manufacturer) users. direct input to a controller or other device is made possible by this sensors near linear voltage output. with a typical current draw of only 200 a, the hih-5030/5031 series is ideally suited for many low drain, battery operated systems. tight sensor interchangeability reduces or eliminates oem production calibration costs. the hih-5030/5031 series delivers instrumentation-quality rh (relative humidity) sensing performance in a competitively priced, solderable smd. the hih-5030 is a covered integrated circuit humidity sensor. the hih-5031 is a covered, condensation-resistant, integrated circuit humidity sensor that is factory-fitted with a hydrophobic filter allowing it to be used in many condensing environments including industrial, medical and commercial applications. the rh sensor uses a laser trimmed, thermoset polymer capacitive sensing element with on-chip integrated signal conditioning. the sensing element's multilayer construction provides excellent resistance to most application hazards such as condensation, dust, dirt, oils and common environmental chemicals. sample packs are available. see order guide. features ? operates down to 2.7 v, often ideal in battery-powered systems where the supply is a nominal 3 v. ? tape and reel packaging allows for use in high volume pick and place manufacturing (1,000 units per tape and reel) ? molded thermoset plastic housing ? near linear voltage output vs %rh ? laser trimmed interchangeability ? low power design ? enhanced accuracy ? fast response time ? stable, low drift performance ? chemically resistant potential applications industrial ? air compressors ? battery-powered systems ? drying equipment ? hvac (includes air conditioning, air movement, thermostats, humidifiers, de-humidifiers, humidistats, enthalpy sensing) ? oem assemblies ? office automation equipment ? process equipment ? refrigeration (includes bulk and transport systems) ? telecommunications cabinets ? weather stations and meteorology equipment medical ? hospital air compressors ? infant incubators ? microenvironments ? sleep apnea equipment ? treadmill stress monitoring equipment
hih-5030/5031 series 2 www.honeywell.com/sensing table 1. performance specifications (at 3.3 vdc supply and 25 c [77 f] unless otherwise noted.) parameter minimum typical maximum unit specific note interchangeability (first order curve) 0% rh to 10% rh, 90% rh to 100% rh 11% rh to 89% rh -7 -3 C C 7 3 % rh % rh C accuracy (best fit straight line) 11% rh to 89% rh -3 C +3 % rh 4 hysteresis C 2 C % rh C repeatability C 0.5 C % rh C settling time C C 70 ms C response time (1/e in slow moving air) C 5 C s C stability (at 50% rh in 5 years) C 1.2 C % rh 1 voltage supply 2.7 C 5.5 vdc 2 current supply C 200 500 a C voltage output (1st order curve fit) v out =(v supply )(0.00636(sensor rh) + 0.1515), typical at 25 c temperature compensation true rh = (sensor rh)/(1.0546 C 0.00216t), t in c output voltage temp. coefficient at 50% rh, 3.3 v C -2 C mv/c C operating temperature -40[-40] see figure 2. 85[185] c[f] C operating humidity (hih-5030) 0 see figure 2. 100 % rh 3 operating humidity (hih-5031) 0 see figure 2. 100 % rh C storage temperature -50[-58] C 125[257] c[f] C storage humidity see figure 3. % rh 3 specific notes: 1. includes stress outside of recommended operating zone. 2. device is tested at 3.3 vdc and 25 c. 3. non-condensing environment. when liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. 4. total accuracy including interchangeability is 3 %rh. general notes: ? sensor is ratiometric to supply voltage. ? extended exposure to > 90 % rh causes a reversible shift of 3 % rh. ? sensor is light sensitive. for best performance, shield sensor from bright light.
low voltage humidity sensors honeywell sensing and control 3 figure 1. operating environment (non-condensing environment for hih-5030 catalog listings only.) figure 2. storage environment (non-condensing environment for hih-5030 catalog listings only.) 0% 10% 20% 30% 50% 40% 60% 70% 80% 90% 100% -40 20 -20 0 40 60 80 100 120 140 temperature oc recommended storage zone
hih-5030/5031 series 4 www.honeywell.com/sensing figure 3. typical output voltage vs relative humidity (at 25 c and 3.3 v.) 0 20 40 60 80 100 0.5 1 2 2.5 3 1.5 relative humidity (%rh) rising rh falling rh figure 4. typical output voltage (bfsl) vs relative humidity (at 0 c, 70 c and 3.3 v.)
low voltage humidity sensors honeywell sensing and control 5 figure 5. hih-5030 mounting dimensions (for reference only. mm/[in]) figure 6. hih-5030 pcb landing pattern (for reference only. mm/[in])
hih-5030/5031 series 6 www.honeywell.com/sensing figure 7. hih-5031 mounting dimensions (for reference only. mm/[in]) figure 8. hih-5031 pcb landing pattern (for reference only. mm/[in])
low voltage humidity sensors honeywell sensing and control 7 figure 9. tape and reel dimensions (for reference only. mm/[in]) figure 10. typical application circuit order guide catalog listing description HIH-5030-001 covered integrated circuit humidity sensor, smd, 1000 units on tape and reel hih-5031-001 covered, filtered integrated circuit humidity sensor, smd, 1000 units on tape and reel HIH-5030-001s sample pack: covered integrated circuit humidity sensor, smd, five units on tape hih-5031-001s sample pack: covered, filtered integrated circuit humidity sensor, smd, sample pack, five units on tape additional humidity sensor information see the following associated literature is available on the web : ? product installation instructions ? application sheets: ? humidity sensor performance characteristics ? humidity sensor theory and behavior ? humidity sensor moisture and psychrometrics ? thermoset polymer-based capacitive sensors
hih-5030/5031 series low voltage humidity sensors sensing and control honeywell 1985 douglas drive north golden valley, mn 55422 www.honeywe ll.com 009050-1-en il50 glo printed in usa may 2009 ? 2009 honeywell international inc. all rights reserved. warning misuse of documentation ? the information presented in this product sheet is for reference only. do not use this document as a product installation guide. ? complete installation, operation, and maintenance information is provided in the instructions supplied with each product. failure to comply with these instructions could result in death or serious injury. warranty/remedy honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. honeywells standard product warranty applies unless agreed to otherwise by honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. if warranted goods are returned to honeywell during the period of coverage, honeywell will repair or replace, at its option, without charge those items it finds defective. the foregoing is buyers sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. in no event shall honeywell be liable for consequential, special, or indirect damages. while we provide application assistance personally, through our literature and the honeywell web site, it is up to the customer to determine the suitability of the product in the application. specifications may change without notice. the information we supply is believed to be accurate and reliable as of this printing. however, we assume no responsibility for its use. warning personal injury do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. failure to comply with these instructions could result in death or serious injury. sales and service honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. for application assistance, current specifications, pricing or name of the nearest authorized distributor, contact your local sales office or: e-mail: info.sc@honeywell.com internet: www.honeywell.com/sensing phone and fax: asia pacific +65 6355-2828 +65 6445-3033 fax europe +44 (0) 1698 481481 +44 (0) 1698 481676 fax latin america +1-305-805-8188 +1-305-883-8257 fax usa/canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 fax


▲Up To Search▲   

 
Price & Availability of HIH-5030-001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X